Typical ADT Water Tanker
- The flow analysis & roll stability was done by Southwest Technologies
- The tank was fitted to a Volvo ADT A40F
- Tank capacity is 35000L
- The tank was fitted with a 80mm Alfa water pump with hydraulic gear driven motor
- A solenoid valve was installed into the hydraulic system to enable the driver to activate the water pump from within the cab
- Hydraulic installation was done by the OEM
- Refilling of the tank has two options:
- The funnel in front top of the tank
- Filling pipe at the back
- The filling pipe at the back can only be used from a separate water pump to pump water out of a different water source into the tank. The piping configuration can be changed so that the existing pump can be used to refill the tank from different water sources
- An air actuating valve was fitted to the water pump to enable the drive open and close the water from within the cab